Industrial Sectional Doors

The sectional door programme in a uniquely wide range

Sectional doors open vertically and thus create more space in front of and behind the door. The door sections are parked flat underneath the ceiling, vertically above the opening or in line with the roof. Series 50 sectional doors, made of steel-SPU, steel/aluminium combination-APU or aluminium-ALR, are set apart by the programme range, top door design and certified security.

Space-saving door system

State-of-the-art operator technology

SPU40 & SPU40 XL

Sturdy double-skinned steel door with good thermal insulation

Maximum size range
  • Width up to 8000 mm (11400 mm for SPU 40 XL)
  • Height up to 7000 mm

Resistance to wind load(EN 12424)  :  Class 3

Water tightness (EN 12425)  :  Class 3 (70 Pa)
Air permeability (EN 12426)
– Without wicket door class 2
– With wicket door class 1
Acoustic insulation (EN 717-1)
– Without wicket door R = 25 dB
– With wicket door R = 24 dB
Thermal insulation (EN 13241-1, appendix B EN 12428)
Without wicket door
– With ThermoFrame U = 0.94 W/ (m²·K)
– Without ThermoFrame U =1.0 W/ (m²·K)
With wicket door
– With ThermoFrame U = 1.2 W/ (m²·K)
– Without ThermoFrame U = 1.2 W/ (m²·K)
Section thermal insulation  :  U = 0.50 W/ (m²·K)
Safety features in acc. with EN 13241-1


APU40

Modern aluminium door with steel bottom section and many versions

Maximum size range
  • Width up to 8000 mm
  • Height up to 7000 mm

Resistance to wind load  :  Class 3

Water tightness (EN 12425)  :  Class 3 (70 Pa)
Air permeability (EN 12426)
– Without wicket door class 2
– With wicket door class 1
Acoustic insulation (EN 717-1)
– Without wicket door R = 23 dB
– With wicket door R = 22 dB
Thermal insulation (EN 13241-1, appendix B EN 12428)
Without wicket door
– Standard double pane with ThermoFrame U = 3.3 W/ (m²·K)
– Standard double pane without ThermoFrame U = 3.4 W/ (m²·K)
With wicket door
– Standard double pane with ThermoFrame U = 3.6 W/ (m²·K)
– Standard double pane without ThermoFrame U = 3.6 W/ (m²·K)
Safety features in acc. with EN 13241-1


ALR40

A modern aluminium door underscores contemporary architecture

Maximum size range
  • Width up to 8000 mm
  • Height up to 7000 mm

Resistance to wind load  :  Class 3

Water tightness (EN 12425)  :  Class 3 (70 Pa)
Air permeability (EN 12426)
– Without wicket door class 2
– With wicket door class 1
Acoustic insulation (EN 717-1)
– Without wicket door R = 23 dB
– With wicket door R = 22 dB
Thermal insulation (EN 13241-1, appendix B EN 12428)
Without wicket door
– Standard double pane with ThermoFrame U = 3.6 W/ (m²·K)
– Standard double pane without ThermoFrame U = 3.6 W/ (m²·K)
with wicket door
– Standard double pane with ThermoFrame U = 3.8 W/ (m²·K)
– Standard double pane without ThermoFrame U = 3.8 W/ (m²·K)
Safety features in acc. with EN 13241-1

Wicket Door

Sectional doors with wicket door and trip-free threshold

Construction: Industrial Sectional Door

The door’s guidance system

 

More light in the building

Section window, aluminium glazing frame

Section window Type A

Aluminium glazing frame

Superior scratch-resistance and thermal insulation of Hörmann sectional door glazings

Manually operated doors

With pull rope or chain hoist

Shaft operator WA 300 S4

With standard soft start and soft stop

Shaft operator WA 400, WA 400 M

Strong, fast and robust